7,605 research outputs found

    Core structure of EAS in 10(15) to 10(17) eV

    Get PDF
    With the use of Akeno calorimeter, the attenuation of particles in concrete is analyzed as the function of the shower size of 10 to the 5th power to 10 to the 7th power. The attenuation length does not depend much on the shower size but depends a little on the shower age. The average value is approx. 150 g/sq cm for s = 0.5 to 0.85 and approx. 40 g/sq cm for s = 0.85 to 1.15. These values and their fluctuations are consistent with the equi-intensity curves of extensive air showers (EAS)

    Analysis of indoor environment and insulation performance of residential house with double envelope vacuum insulation panels

    Get PDF
    Double envelope vacuum insulation panels (VIPs) have a possibility to significantly increase the service lifetime. In this paper, double envelope VIPs were produced and installed in the residential house. The performance of installed VIPs was evaluated by using the measuring data of heat flux meter. In addition, the total energy, the heating load and the indoor thermal environment of this house were measured and analysed. The average heating load and the average temperature difference between room temperature and ambient air temperature on the representative day was 2.49 kW and 29.9 oC, respectively. The heat loss coefficient per floor area was estimated as 0.69 W/(m2K) and it was almost the same as the value calculated at the time of design. The result of indoor environment measurement showed that the room temperature was maintained at around 20 oC and PMV was -0.5 oC or higher although the outside air temperature fluctuated between -5 oC and -10 oC. The effective thermal conductivities of double envelop VIPs were all estimated as 0.01 W/(mK) or less. It is considered that the insulation performance of the vacuum insulation panels is maintained

    Measurement of energy muons in EAS at energy region larger thean 10(17) eV

    Get PDF
    A measurement of low energy muons in extensive air showers (EAS) (threshold energies are 0.25, 0.5, 0.75 and 1.38 GeV) was carried out. The density under the concrete shielding equivalent to 0.25 GeV at core distance less than 500 m and 0.5 GeV less than 150 m suffers contamination of electromagnetic components. Therefore the thickness of concrete shielding for muon detectors for the giant air shower array is determined to be 0.5 GeV equivalence. Effects of photoproduced muons are found to be negligible in the examined ranges of shower sizes and core distances. The fluctuation of the muon density in 90 sq m is at most 25% between 200 m and 600 m from the core around 10 to the 17th power eV

    Experimental analysis of vacuum pressure and gas flow rate in structured-core transparent vacuum insulation panels

    Get PDF
    The notion that modern buildings should strive to be net-zero energy buildings (NZEBs) is widely accepted. One of the causes leading to high energy usage for space heating, resulting in avoidable carbon emissions, is heat loss via building windows. In order to improve window’s insulation in existing buildings, structured-core transparent vacuum insulation panels (TVIPs) are proposed. TVIPs mainly consist of the structured core material, the low-emissivity film, and the transparent gas barrier envelope. TVIPs have high insulation performance and are inexpensive to manufacture and can be easily installed. Therefore, TVIPs have the potential to improve window’s insulation in existing buildings at a low cost. However, it is necessary to overcome the issue of preventing the pressure rise inside TVIP after vacuum sealing. The authors constructed an experimental setup to quantify the effect of reduction of gas flow rate in TVIP after evacuation by applying the pressure-rate-of-rise-method. In this experiment, a gas barrier film with a straw was used as the vacuum chamber. This could reproduce the pressure increase in the TVIP after sealing and the gas flow rate in the TVIP is evaluated. The experimental result shows that the coated core material and the enclosing getter agent lowered the pressure rise and gas flow rate in TVIP by combining concurrent evacuation and heating. Furthermore, after extending the simultaneous vacuuming and heating period to 8 h and applying the coated core material, and enclosing the getter agent, the internal pressure in TVIP may be lowered to around 1 Pa after 30 min after halting vacuuming. It was confirmed that this pressure satisfied the performance required for TVIPs, and the result was much closer to the realization of TVIPs

    EAS development curve at energy of 10(16) - 10(18) eV measured by optical Cerenkov light

    Get PDF
    The data of optical Cerenkov light from extensive air shower observed at the core distance more than 1 Km at Akeno are reexamined. Applying the new simulated results, the shower development curves for the individual events were constructed. For the showers of 10 to 17th power eV the average depth at the shower maximum is determined to be 660 + or - 40 gcm/2. The shower curve of average development is found to be well described by a Gaisser-Hillas shower development function with above shower maximum depth

    Probe of CP Violation in e+e- -> ttbar Near Threshold

    Get PDF
    We study how to probe the anomalous CP-violating couplings of top quark with photon, Z and gluon in the ttbar threshold region at future e+e- colliders. These couplings contribute to the difference of the t and tbar polarization vectors delta P and to the CP-odd spin correlation tensor delta Q_ij. We find that typical sizes of delta P and delta Q_ij are 5-20% times the couplings (d_tgamma, d_tZ, d_tg) in the threshold region. Experimentally delta P can be measured efficiently using the CP-odd combination of the l+/l- momenta or of the l+/l- directions. We have similar sensitivities to both the real and imaginary parts of the couplings independently using the two components of delta P. Taking advantage of different dependences of delta P on the e+/e- polarizations and on the c.m. energy, we will be able to disentangle the effects of the three couplings d_tgamma, d_tZ, d_tg in the ttbar threshold region. We give rough estimates of sensitivities to the anomalous couplings expected at future e+e- colliders. The sensitivities to d_tgamma and d_tZ are comparable to those attainable in the open-top region at e+e- colliders. The sensitivity to d_tg is worse than that expected at a hadron collider but exceeds the sensitivity in the open-top region at e+e- colliders.Comment: 25 pages, 9 figure
    corecore